…by means of the DSC 214 Nevio ‒ the fastest heat-flux DSC instrument on the market.
Information obtained by differential scanning calorimetry (DSC):
- Melting temperatures and enthalpies
- Polymorphism
- Crystallization temperatures and enthalpies
- Glass transitions
- Solid-solid interactions (e.g., compatibility)
- Phase diagrams
- Eutectic purity
- Solid-fat content
- Reaction temperatures and enthalpies
- Cross-linking reactions (curing)
- Oxidation-induction time and temperature (OIT (isothermal), OIT (dynamic), OOT)
Features of the DSC 214 Nevio:
Intelligent software – AutoEvaluation and Identify
AutoEvaluation, a unique feature of the Proteus software, evaluates endothermic or exothermic effects fully automatically with just one click. The result of this evaluation can serve as a second opinion when assessing samples of unknown composition. Identify is a database system for curve recognition and interpretation. The included libraries currently contain more than 1200 entries. However, customers can easily create their own libraries and expand them with own measurements.
Compactness
With its space-saving design, the DSC 214 Nevio fits into even the smallest of labs.
Everything in one package
Even the basic version of the instrument comes with everything necessary to perform measurements correctly and evaluate them successfully.
Ready if you need it
Using the SetPoint function, it is possible to schedule the day and time when the cooling device and the gas flow should be active, so the DSC is always ready for work right on time.
Perfectly synchronized sensor/crucible system
A Concavus pan, which features a concave outer bottom, forms a clearly defined, ring-shaped contact zone when positioned on the sensor. This results in optimum reproducibility.
The automatic sample changer (ASC) works overnight or during the weekend
Up to 19 samples – either belonging to a single series or independent of each other – can be handled with the optional automatic sample changer without operator intervention. This frees up time to focus on other important tasks.
The ProteusProtect software meets the requirements of 21 CFR Part 11.
Technical Data
Temperature range (max.)
Measuring range
Max. cooling rate/max. heating rate
Enthalpy accuracy:
< 1%**
TGA resolution:
n/a
Indium Response Ratio (*):
> 100
Exchangeable sensors:
n/a
Cooling options:
Air compressor: RT to 600°C
Compressed air: < 0°C to 600°C
Intracooler: -70°C to 600°C
Liquid nitrogen: -170°C to 700°C
Gas atmospheres:
Inert, oxidizing, static and dynamic
Mass flow controller for purge/protective gas:
3, integrated (0 to 250 ml/min)
Gas flow regulation:
Software-controlled
Automatic Sample Changer (ASC):
Yes (optional)
* minus weight of crucible
** for indium
Software:
min. Proteus 8
Proteus software extensions included:
SmartMode
ExpertMode
AutoCalibration
(Advanced) BeFlat
AutoEvaluation
Identify
Proteus software extensions (optional):
Temperature modulation
Specific heat capacity (cp)
Proteus Protect
Purity Determination
Advanced Software extensions (optional):
Peak Separation
Kinetics Neo
Thermal Simulations
Size (W x H x D) – incl. ASC, without physical connections:
350 mm x 445 mm x 560 mm
This instrument is LabV®️-primed
LabV®️ takes the data from your analytical instrument: It automatically imports all measurement data into a central and secure database solution, the LabV®️ software. This allows you to visualize the data in LabV®️ and to make them searchable. Your data will now be accessible from anywhere. Moreover you have the possibility to generate reports.